Calibration Options for Biofuel Analyzers

Several calibration options are available for the Biofuel Blend Analyzers:

  • Customer prepared standards for ethanol or biodiesel calibration as described in the User's Guides
  • Packaged ethanol or biodiesel calibration standards available for purchase from Wilks Enterprise (ordering information is provided below)
  • Pre-calibration by Wilks Enterprise (non-certified factory calibration, as described below)

Standards
Standards can be made gravimetrically or volumetrically as described in the manual.   Pre-packaged biodiesel and ethanol calibration standards prepared by a certified laboratory are available for purchase from Wilks Enterprise. These standards have been prepared by weight (mg/ml) by an ISO-9001 registered laboratory. .

Non-Certified Factory Calibration
Wilks Enterprise can provide the InfraCal Biodiesel Blend Analyzer, InfraCal Ethanol Blend Analyzer of InfraSpec VFA-IR Spectrometer with a non-certified 6-point factory calibration using the ethanol blend and biodiesel blend calibration standards that we have available for sale. Please contact Wilks Enterprise Inc. for pricing.

Calibration Standard Sets

403-1024

10 Point Biodiesel Calibration Standard Set
Standards range from 0 – 100% biodiesel in diesel fuel. Standards are prepared by a certified laboratory.  Each vial contains 20 ml of standard, good for a minimum of 15 tests.  For use with InfraCal Biodiesel Blend Analyzer and InfraSpec VFA-IR Spectrometer, Models E and ES.

403-1050

10 Point Biodiesel Calibration Standard Set
Standards range from 0 – 30% biodiesel in diesel fuel. Standards are prepared by a certified laboratory.  Each vial contains 20 ml of standard, good for a minimum of 15 tests.  For use with InfraCal Biodiesel Blend Analyzer and InfraSpec VFA-IR Spectrometer, Models E and ES.

403-1026

5 Point Ethanol Low Concentration Calibration Standard Set
Standard concentrations are 0, 5, 10, 15, and 20% ethanol in gasoline. Standards are prepared by a certified laboratory. Each vial contains 15 ml of standard, good for a minimum of 10 tests.
For use with InfraCal Ethanol Blend Analyzer and InfraSpec VFA-IR Spectrometer, Models E and ES.

403-1027

5 Point Ethanol High Concentration Calibration Standard Set
Standard concentrations are 70, 80, 90, 95, and 100% ethanol in gasoline.  Standards are prepared by a certified laboratory. Each vial contains 15 ml of standard, good for a minimum of 10 tests. For use with InfraCal Ethanol Blend Analyzer and InfraSpec VFA-IR Spectrometer, Model ES.

Non-Certified Factory Calibration Options for InfraCal Biofuel Analyzers

403-1028

Non-Certified Factory Calibration for the InfraCal Biodiesel Blend Analyzer
Non-certified 10-point factory calibration for biodiesel in diesel with certified calibration standards, P/N 403-1050.  The calibration range is 0 to 30% biodiesel.

403-1056 Non-Certified Factory Calibration for the InfraCal Biodiesel Blend Analyzer
Non-certified 10-point factory calibration for biodiesel in diesel with certified calibration standards, P/N   403-1024.  The calibration range is 0 to 100% biodiesel.

403-1029

Non-Certified Factory Calibration for EITHER 5 point Low Concentration Calibration or 5 point High Concentration Calibration for the InfraCal Ethanol Blend Analyzer
Non-Certified 5-point Factory Calibration for either 0-20% ethanol in gasoline or 70-100% ethanol in gasoline with certified calibration standards.(Please specify range when ordering)

403-1030

Non-Certified Factory Calibration for BOTH 5 point Low Concentration Calibration and 5 point High Concentration Calibration for the InfraCal Ethanol Blend Analyzer
Non-Certified 5-point Factory Calibration for both 0-20% ethanol in gasoline and 70-100% ethanol in gasoline with certified calibration standards.

Non-certified Factory Calibration for InfraSpec Biofuel Analyzers

403-1031

Non-Certified Factory Biodiesel Calibration for the InfraSpec VFA-IR Spectrometer, Model E or ES
Non-certified 10-point factory calibration for biodiesel in diesel with certified calibration standards.  The calibration range is 0 to 100% biodiesel.

403-1032

Non-Certified Factory Calibration for EITHER 5 Point Ethanol Low Concentration Calibration or 5 Point Ethanol High Concentration Calibration for the InfraSpec VFA-IR Spectrometer Model ES
Non-Certified 5-point Factory Calibration for either 0-20% ethanol in gasoline or 70-100% ethanol in gasoline with certified calibration standards.(Please specify range when ordering)

403-1033

Non-Certified Factory Ethanol Calibration for BOTH 5 Point Ethanol Low Concentration Calibration and 5 Point Ethanol High Concentration Calibration for the InfraSpec VFA-IR Spectrometer Model ES
Non-Certified 5-point Factory Calibration for both 0-20% ethanol in gasoline and 70-100% ethanol in gasoline with certified calibration standards.