Several calibration options are available for the Biofuel Blend Analyzers:
- Customer prepared standards for ethanol or biodiesel calibration as described in the User's Guides
- Packaged ethanol or biodiesel calibration standards available for purchase from Wilks Enterprise (ordering information is provided below)
- Pre-calibration by Wilks Enterprise (non-certified factory calibration, as described below)
Standards Standards can be made gravimetrically or volumetrically as described in the manual. Pre-packaged biodiesel and ethanol calibration standards prepared by a certified laboratory are available for purchase from Wilks Enterprise. These standards have been prepared by weight (mg/ml) by an ISO-9001 registered laboratory. .
Non-Certified Factory Calibration Wilks Enterprise can provide the InfraCal Biodiesel Blend Analyzer, InfraCal Ethanol Blend Analyzer of InfraSpec VFA-IR Spectrometer with a non-certified 6-point factory calibration using the ethanol blend and biodiesel blend calibration standards that we have available for sale. Please contact Wilks Enterprise Inc. for pricing.
|
Calibration Standard Sets
|
|
403-1024
|
10 Point Biodiesel Calibration Standard Set Standards range from 0 – 100% biodiesel in diesel fuel. Standards are prepared by a certified laboratory. Each vial contains 20 ml of standard, good for a minimum of 15 tests. For use with InfraCal Biodiesel Blend Analyzer and InfraSpec VFA-IR Spectrometer, Models E and ES.
|
| 403-1050 |
10 Point Biodiesel Calibration Standard Set Standards range from 0 – 30% biodiesel in diesel fuel. Standards are prepared by a certified laboratory. Each vial contains 20 ml of standard, good for a minimum of 15 tests. For use with InfraCal Biodiesel Blend Analyzer and InfraSpec VFA-IR Spectrometer, Models E and ES.
|
|
403-1026
|
5 Point Ethanol Low Concentration Calibration Standard Set Standard concentrations are 0, 5, 10, 15, and 20% ethanol in gasoline. Standards are prepared by a certified laboratory. Each vial contains 15 ml of standard, good for a minimum of 10 tests. For use with InfraCal Ethanol Blend Analyzer and InfraSpec VFA-IR Spectrometer, Models E and ES.
|
|
403-1027
|
5 Point Ethanol High Concentration Calibration Standard Set Standard concentrations are 70, 80, 90, 95, and 100% ethanol in gasoline. Standards are prepared by a certified laboratory. Each vial contains 15 ml of standard, good for a minimum of 10 tests. For use with InfraCal Ethanol Blend Analyzer and InfraSpec VFA-IR Spectrometer, Model ES.
|
Non-Certified Factory Calibration Options for InfraCal Biofuel Analyzers |
|
403-1028
|
Non-Certified Factory Calibration for the InfraCal Biodiesel Blend Analyzer Non-certified 10-point factory calibration for biodiesel in diesel with certified calibration standards, P/N 403-1050. The calibration range is 0 to 30% biodiesel.
|
| 403-1056 |
Non-Certified Factory Calibration for the InfraCal Biodiesel Blend Analyzer Non-certified 10-point factory calibration for biodiesel in diesel with certified calibration standards, P/N 403-1024. The calibration range is 0 to 100% biodiesel. |
|
403-1029
|
Non-Certified Factory Calibration for EITHER 5 point Low Concentration Calibration or 5 point High Concentration Calibration for the InfraCal Ethanol Blend Analyzer Non-Certified 5-point Factory Calibration for either 0-20% ethanol in gasoline or 70-100% ethanol in gasoline with certified calibration standards.(Please specify range when ordering)
|
|
403-1030
|
Non-Certified Factory Calibration for BOTH 5 point Low Concentration Calibration and 5 point High Concentration Calibration for the InfraCal Ethanol Blend Analyzer Non-Certified 5-point Factory Calibration for both 0-20% ethanol in gasoline and 70-100% ethanol in gasoline with certified calibration standards.
|
Non-certified Factory Calibration for InfraSpec Biofuel Analyzers
|
|
403-1031
|
Non-Certified Factory Biodiesel Calibration for the InfraSpec VFA-IR Spectrometer, Model E or ES Non-certified 10-point factory calibration for biodiesel in diesel with certified calibration standards. The calibration range is 0 to 100% biodiesel.
|
|
403-1032
|
Non-Certified Factory Calibration for EITHER 5 Point Ethanol Low Concentration Calibration or 5 Point Ethanol High Concentration Calibration for the InfraSpec VFA-IR Spectrometer Model ES Non-Certified 5-point Factory Calibration for either 0-20% ethanol in gasoline or 70-100% ethanol in gasoline with certified calibration standards.(Please specify range when ordering)
|
|
403-1033
|
Non-Certified Factory Ethanol Calibration for BOTH 5 Point Ethanol Low Concentration Calibration and 5 Point Ethanol High Concentration Calibration for the InfraSpec VFA-IR Spectrometer Model ES Non-Certified 5-point Factory Calibration for both 0-20% ethanol in gasoline and 70-100% ethanol in gasoline with certified calibration standards.
|