WilksIr - Oil, Water, Soil, Gas analyzers

InfraRan Specific Vapor Analyzers

Model

InfraRan Specific Vapor Analyzers

InfraRan Specific Vapor Analyzers
Optional Models Available

The InfraRan Specific Vapor Analyzer is portable fixed filter infrared analyzer factory calibrated for easy, on-site ambient air measurements of a specific gas or gases. This easy-to-use portable analyzer is ideal for measuring single or multiple anesthetic gases, SF6 for ASHRAE 110 evaluations or leak detection, single or multiple refrigerant gases, various solvent vapors, as well as numerous other infrared absorbing gases. The analyzer's user-friendly software prompts the operator through the analysis and real-time concentration levels are displayed in either parts per million (ppm) or percent (%). Ideal for users who require a cost effective solution for precise spot measurements of specific gases.

The InfraRan Specific Vapor Analyzer can be factory-calibrated to monitor a specific gas or gases. Below is a list of typical gases. Click here for a list
typical gases and measurement ranges or contact us for other gases and measurement ranges of interest.

Gas Calibration Code Gas Concentration Range LImit Wavelength Detection Limit cell Pathlength

1001

Acetone

0-1000

8.2um

5 ppm

Long

1002

Carbon Dioxide (CO2)

0-3000

4.25um

3 ppm

Short

1003

Carbon Monoxide

0-100

461um

1 ppm

Long

1004

Carbon Tetrachloride

0-25

12.6um

0.1 ppm

Long

1005

Desflurane

0-50

8.5um

0.1 ppm

Long

1006

General Hydrocarbons as Hexane

0-500

3.33um

0.5 ppm

Long

1007

Isoflurane

0-50

8.8um

0.1 ppm

Long

1008

Isoprpyl Alchohol (IPA)

0-500

8.8um

2 ppm

Long

1009

Methylene Chloride

0-100

13.2um

2 ppm

Long

1010

Nitrous Oxide

0-100

4.5um

0.1 ppm

Long

1011

Perchloroethylene

0-50

10.9um

0.1 ppm

Long

1012

R-114

0-2000

8.38um

10 ppm

Short

1013

R-12

0-2000

9.1um

10 ppm

Short

1014

R-134A

0-2000

8.05um

10 ppm

Short

1015

R236fa

0-2000

8.38um

10 ppm

Short

1016

Sevoflurane

0-50

8.05um

0.1 ppm

Long

1018

Toluene

0-200

13.8um

1ppm

Long

Please note: Other gases, ranges and wavelengths are available on special order. Please contact Wilks for details or complete and return the InfraRand Application Feasibility Form.

Applications

Applications

The InfraRan Specific Vapor Analyzer is a filter based infrared analyzer that is preset and calibrated for a specific gas or gases. Our most common applications are listed below:

  • InfraRan SF6 Analyzer for Fume Hood Testing
    A safe laboratory environment requires an effective method for clearing toxic material from fume hoods. Since all handling of toxic materials is completed in these hoods, it is critical to have a procedure to evaluate their operation to assure adequate protection for laboratory workers. The InfraRan Specific Vapor Analyzer, calibrated for SF6, is an ideal instrument for measuring fume hood efficiency in accordance with ASHRAE and other standards.
  • Anesthetic Gases
    Ensuring that workers in surgical operating rooms, dental and veterinary offices, and postoperative recovery rooms are not exposed to high levels of waste anesthetic gases is important to avoid health risks due to chronic exposure. InfraRan Specific Vapor Analyzers, factory calibrated for measuring up to 4 anesthetic gases, are ideal for on-site measurement of waste anesthetic gas as part of a preventative maintenance program to identify leaks on anesthetic delivery systems, as well as in the entire patient monitoring system during actual operating procedures.
  • Refrigerant Leak Detection
    The InfraRan Specific Vapor Analyzer has been used for many years by the British MOD onboard submarines for refrigerant gas leak detection to ensure safe air quality conditions. The analyzer can be calibrated for up to 4 gases.

Ordering Information

Ordering Information

Part Number Description
405-2000-XXXX
Note: Last four digits indicate Gas Calibration Code
InfraRan Single-Gas Specific Vapor Analyzer. Single-beam infrared spectrophotometer with fixed wavelength filter/detector for measuring single gas and concentration range (see table below). Includes menu-driven software and factory calibration for specified gas, internal battery pack with external charger and power supply (85 - 250 VAC, 50 - 60 Hz, universal input), RS232 and USB communication ports, sampling wand, two charcoal zero filters and shoulder strap.
405-2000-1017 InfraRan SF6 Single-Gas Analyzer. Single-beam infrared spectrophotometer with fixed wavelength filter/detector for measuring sulfur hexafluoride (SF6) in the 0-10 ppm concentration range with 0.01 ppm detection limit. Includes menu-driven software and factory calibration for SF6, internal battery pack with external charger and power supply (85 - 250 VAC, 50 - 60 Hz, universal input), digital and analog outputs, RS232 and USB communication ports, sampling wand, two charcoal zero filters and shoulder strap. Ideal for determining Chemical Fume Hood (ASHARAE 110) or Room Flow Rate Efficiencies.
405-2005-0001 InfraRan 4-Gas Anesthetic Specific Vapor Analyzer for measuring anesthetic gases individually. Single beam infrared spectrophotometer with four-wavelength filter/detector for measuring Nitrous Oxide (0 – 100 ppm), Desflurane (0 – 50 ppm), Isoflurane (0 – 50 ppm) and Sevoflurane (0 – 50 ppm). Includes menu-driven software and factory calibration for the above anesthetic gases, internal battery pack with external charger and power supply (85 – 250 VAC, 50 – 60 Hz, universal input), RS232 and USB communications ports, sampling wand, two charcoal zero filters and shoulder strap.
405-2004
InfraRan 4-Gas Refrigerant Specific Vapor Analyzer Single beam infrared spectrophotometer with fixed wavelength/detector for measuring R114, R134a, R236a and Halon 13B1 in the 0 – 2500 ppm concentration range. Includes menu-driven software and factory calibration for R114, R134a, R236a, and Halon 13B1, internal battery pack with external charger and power supply
(85 – 250 VAC, 50 – 60 Hz, universal input), RS232 and USB communications ports, sampling wand, two charcoal zero filters and shoulder strap.
Accessories
403-1019 Analog Output for InfraRan Analyzer. This option should be specified and ordered with the purchase of the InfraRan Analyzer. Included as standard with P/N 405-2000-1017 InfraRan SF6 Single-Gas Analyzer.
403-1015 Travel Case for InfraRan Analyzer with diced foam, reinforced extendable handle, large 3 inch wheels, stainless steel twist-lock latches and spring loaded steel handles.Approximately 27” x 18” x 13”.
Expendables
500-0022 Charcoal Zero Filter, 2 pack
205-1029 Particulate Filter
Replacement Parts
201-0001 Replacement 12v NiMH Battery Pack
405-2024 Battery Charger Assembly including battery charger, power cord with ferrite and connecting cable for connecting the InfraRan Analyzer to the battery charger.
405-2027 Zero Filter Holder
405-1022 Replacement Sampling Wand Assembly with flexible hose and particulate filter
211-0004 Shoulder Strap

Calibration - Typical Gases

Calibration - Typical Gases

The InfraRan Specific Vapor Analyzer can be factory-calibrated to monitor a specific gas or gases. Below is a list of typical gases. Click here for a list
typical gases and measurement ranges or contact us for other gases and measurement ranges of interest.

Gas Calibration Code Gas Concentration Range LImit Wavelength Detection Limit cell Pathlength

1001

Acetone

0-1000

8.2um

5 ppm

Long

1002

Carbon Dioxide (CO2)

0-3000

4.25um

3 ppm

Short

1003

Carbon Monoxide

0-100

461um

1 ppm

Long

1004

Carbon Tetrachloride

0-25

12.6um

0.1 ppm

Long

1005

Desflurane

0-50

8.5um

0.1 ppm

Long

1006

General Hydrocarbons as Hexane

0-500

3.33um

0.5 ppm

Long

1007

Isoflurane

0-50

8.8um

0.1 ppm

Long

1008

Isoprpyl Alchohol (IPA)

0-500

8.8um

2 ppm

Long

1009

Methylene Chloride

0-100

13.2um

2 ppm

Long

1010

Nitrous Oxide

0-100

4.5um

0.1 ppm

Long

1011

Perchloroethylene

0-50

10.9um

0.1 ppm

Long

1012

R-114

0-2000

8.38um

10 ppm

Short

1013

R-12

0-2000

9.1um

10 ppm

Short

1014

R-134A

0-2000

8.05um

10 ppm

Short

1015

R236fa

0-2000

8.38um

10 ppm

Short

1016

Sevoflurane

0-50

8.05um

0.1 ppm

Long

1018

Toluene

0-200

13.8um

1ppm

Long

Please note: Other gases, ranges and wavelengths are available on special order. Please contact Wilks for details or complete and return the InfraRand Application Feasibility Form.

Specs

Specifications

Instrument Type Fixed Filter Infrared Analyzer
Power Requirements (Battery Charger – External Operating Supply) 120-220V AC – 50/60 Hz
Battery Pack Rechargeable Nickel Metal Hydride 12V; 9 Ah capacity
Dimensions 15" x 7.3" x 7.5" (381 mm x 185 mm x 191 mm)
Mass 18 lbs (8.2 kg)
Enclosure High Impact Polymer
Type Single Beam Infrared Spectrophotometer
Optics Cell 1st Surface Gold & Pyrex Photometer, Fixed Band Pass Filters (specific to the gas or gases to be measured)
Cell Pathlength 6.0 Meter (256") is used for most gases - for a high concentration range of a specified gas or gases, a 1.2 meter or 16 cm cell may be used
Sample Cell Volume 0.45 liters (0.0159 ft3 )
Sample Flow 10 liter per min (21.2 ft3/hr)
Gas Purge 5 Cell Volumes for 99% purge of cell (approx. 5 sec @ 10 liters/min)
Measurement Cycle Display Updated Every Second
Source Thin film on diamond-like carbon support
Communications Port Data Output USB and RS232 for Connection with PC
Concentration Alarm High & Low (selectable by user)
Display Vacuum Fluorescent - 8 Lines x 40 Characters Plasma Display
Key Pad 20 Key Tactile Keypad

Warranty

Warranty

All InfraRan Analyzers come with a One Year Factory Warranty against defective parts and workmanship. Should the analyzer be used improperly and damage the gas cell, repair of the gas cell will not be covered under the warranty. Expendable items, such as the particulate filter and charcoal filters, are not covered by the warranty.

request quote 

Copyright © 2014 Spectro Scientific. All Rights Reserved.
Wilks, InfraCal, InfraSpec and InfraRan are trademarks of Spectro Scientific
Analyzers for practical and easy on-site measurements